Specialty
Noise / Vibration
SECTOR
Industrial
Municipal
TYPE
Permitting / Compliance
CLIENTELE
Private Sector
TIMESPAN
2014LOCATION
Stamford, CT
Project Number:
3893Industrial Building - Stamford
SERVICE:
Noise Wall Evaluation
DESCRIPTION:
Tech was asked to perform acoustic modeling for a proposed sound wall in an industrial area located near a residential development. Because of the closeness of the industrial building to the residential area, Tech determined that the constructed sound wall would have to accomplish two things. The wall needed to block the line-of-sight and rise above the sight-line of the 3-story buildings. This would ensure the sound is sufficiently diffracted and adequate attenuation would be provided. The effectiveness of the barrier would be judged on the achievement of a noticeable sound difference (5 dBA or more). Tech provided an analysis of numerous sound barriers, all at different heights, and the associated reduction in sound. They found that a decrease in 5 dBA or more was first achieved with a barrier of 18 feet or more. Tech's recommendation was to build a sound barrier wall that was 18-20 feet high to achieve the most noticeable sound reduction.