Project Number:

3796

Legacy Farms Development

SERVICE:

Sound Compliance Monitoring

DESCRIPTION:

Tech was asked to perform sound compliance monitoring at the Legacy Farms development to demonstrate compliance with the U.S. Department of Housing and Urban Development Site Acceptability Standard. The Standard is a Day-Night (Ldn) sound level limit of 65 dBA. The Ldn is the 24-hour average sound level associated with a 10 dB penalty during the nighttime hours. Tech setup a sound monitoring system for a 24-hour period following ANSI protocols for proper sound level monitoring and equipment placement. Tech analyzed the data per HUD Environmental Criteria and Standards to obtain the measured Ldn level. The calculated level, 55.3 dBA, was below the standard of 65 dBA allowing Tech to conclude that the site would be suitable for housing under HUD's Site Acceptability Criteria.

Print   Email

Key Points

  • Tech performed sound monitoring to assess compliance with the HUD Site Acceptability Standard of 65 dBA for a day-night sound level limit.
  • Using data collected over a 24-hour period, Tech was able to conclude that the results would comply with the HUD standard and the site was suitable for housing.